Time range for detecting blood stains with Luminol

Release time:

2023-11-13


Luminol reagent is a chemiluminescent reagent widely used in crime scene investigations and forensic fields, mainly for detecting blood stains. Its uniqueness lies in its ability to recognize the presence of bleeding cell components even after prolonged cleaning or friction. However, there is a common misconception about the time range for detecting blood stains with Luminol. This article will explore the time range for detecting blood stains and the factors that affect their detection effectiveness.

Firstly, it should be clarified that Luminol reagents are not omnipotent. Its detection effectiveness is influenced by various factors, including the freshness of blood stains, the degree of cleaning, and the use of reagents. Therefore, it is not possible to simply provide a definite detection time range.

Generally speaking, fresh blood stains are more easily detected. This is because fresh blood contains more iron ions and other metal ions, which can catalyze the luminescence reaction of luminol reagents. However, over time, the metal ions in the bloodstains will gradually decrease, thereby affecting the detection effect.

In addition, cleaning and rubbing can also reduce the metal ions in the bloodstains, reducing the detection effectiveness of the Luminol reagent. Therefore, even if the blood stain does not exist for a long time, it may not be detected if cleaned or rubbed.

However, this does not mean that old blood stains cannot be detected. In some cases, even if the blood stain has been present for a period of time, the Luminol reagent can still detect metal ions in it, thereby confirming the existence of the blood stain.

Overall, the time range for detecting blood stains with Luminol reagent is influenced by various factors, including the freshness of the blood stains, the degree of cleaning, and the method of using the reagent. Therefore, it is not possible to simply provide a definite detection time range. In practical applications, it is necessary to make judgments and use them based on specific circumstances

Desheng has been committed to the research of chemiluminescent reagents for nearly 20 years, constantly breaking through, striving for progress while maintaining stability, and serving customers is our goal. The products we produce have received unanimous praise from domestic and foreign customers. Currently, our Lumino is sold to more than 100 domestic and foreign customers and can be used in various industries. If you also have purchasing needs, please feel free to contact us!